当前位置:首页  >  产品展示  >  有机混标  >  农药混标  >  标准品/丙酮中27种农药混标

标准品/丙酮中27种农药混标
参考价:¥2000

型号:

更新时间:2023-08-08  |  阅读:1149

详情介绍

丙酮中27种农药混标

Reference Material

This certificate is designed in accordance with ISO 17034 and ISO Guide 31. This reference material (RM) was designed,produced and verified in accordance with ISO/IEC 17025ISO 17034 and a registered quality management system ISO 9001.

Product Name 27 Pesticide Mix in Acetone,100μg/mL
Part Number 81461a
 
Lot Number 21080231
Expiry Date 2022-Aug-18
 
Storage           -18℃,Keep in the shade
CERTIFIED
Component
No.
Peak
Sequence
ComponentCAS No.Concentration
(μg/mL)
Uncertainty
(%)
11Methamidophos10265-92-61003
22Dichlorvos162-73-71003
33Acephate30560-19-11003
44Omethoate1113-02-61003
55Ethoprophos13194-48-41003
66Monocrotophos6923-22-41003
77Dimethoate60-51-51003
88Terbufos13071-79-91003
99Diazinon333-41-51003
1010Chlorpyrifos-methyl5598-13-01003
11Parathion-methyl298-00-01003
1211Fenitrothion122-14-51003
1312Malathion121-75-51003
1413Fenthion55-38-91003
1514Chlorpyrifos2921-88-21003
16Parathion56-38-21003
1715Isocarbofos24353-61-51003
1816Isofenphos-methyl99675-03-31003
1917Methidathion950-37-81003
2018Tetrachlorvinphos22248-79-91003
2119Profenofos41198-08-71003
2220Ethion563-12-21003
2321Triazophos24017-47-81003
2422EPN2104-64-51003
2523Phosalone2310-17-01003
2624Trichlorfon152-68-61003
2725Phoxim114816-18-31003

C H R O M A T O G R A M


Note:
1.  Dichlorvos(CAS No. :62-73-7),Trichlorfon(CAS No. :52-68-6) and Phoxim(CAS No. :14816-18-3) were tested by LC-MS/MS.


 
 Instrument
  GC/FID
 Column
  HP-5(30m×0.32mm×0.25μm)
 Injection Temp
  250℃
 Detector Temp
  280℃
 Method Details 

  60℃,40℃/min→130℃(1min),
  12℃/min→180℃(1min),7℃/min
  →240℃,5℃/min→260℃(3min)
Intended Use

This RM is intended for use in a laboratory as a calibration and quality control standard or in method development for analytical techniques.

Uncertainty

The certified value(s) and uncertainty(ies) are determined in accordance with ISO 17034 with an 95% confidence level (k=2). Uncertainty is based on the Total Combined Uncertainty, including uncertainties of preparation, purity of neat materials, homogeneity, stability testing.

Traceability

The balances used for gravimetric measurements are calibrated with weights traceable to the national standards. The calibration of the balances is verified annually by an external accredited calibration service. This analysis method has been verified using an approach consistent with ISO 17034:2016 & ISO 17025:2017.

Homogeneity

Random replicate samples of the final packaged RM have been analysed to prove homogeneity consistent with ISO 17034.

Storage

The RM should be stored in the original sealed bottle at the indicated temperature.


  • * 姓名:

  • * 电话:

  • * 单位:

  • * 验证码:

  • * 留言内容:

电话 询价

产品目录